Author Fairhall, M. url  openurl
  Title An observational study of Peripherally Inserted Central Cather(PICC)-related complications amongst oncology patients Type (up)
  Year 2008 Publication Abbreviated Journal ResearchArchive@Victoria  
  Volume Issue Pages  
  Keywords Patient safety; Equipment and Supplies; Nursing specialties; Cancer; Oncology  
  Abstract This thesis reports on a retrospective observational study that examined the complication rate of peripherally inserted central catheters (PICCs) within a regional cancer centre. PICCs are increasingly used for delivery of chemotherapy and other intravenous therapies in oncology patients. A literature review revealed that almost all published research on PICC complications reported on silicone (Groshong(TM)) catheter use, rather than the polyurethane (Arrow(TM)) PICCs used at Christchurch Hospital. Also, much literature referred to PICCs being inserted by non-nurses, whereas the Christchurch service uses specially-trained nurses to insert them. The purpose of the study was to identify the nature, incidence and rates of polyurethane (Arrow(TM)) PICC complications in an adult oncology cohort. Ethics Committee approval was gained to retrospectively follow all PICCs inserted in adult oncology patients at Christchurch Hospital over a 13-month period from 1st March 2006 until 31st March 2007. Data collected were analysed utilising the statistical computer package SPSS. One hundred and sixty-four PICCs were inserted into 156 individual oncology patients over this period. The median dwell time was 68 days for a total of 14,276 catheter-days. Complications occurred in 25 (15%) out of 164 PICC lines, in 22 (15%) of the 156 patients for an overall complication rate of 1.75 per 1000 catheter-days. However, only 16 of the 25 PICCs with complications required early removal (9.75% of the cohort) for a favourably low serious complication rate of 1.12 per 1000 catheter-days. The three commonest complications were infection at 4.3% (7/164) or 0.49 infection complications/1000 PICC-days, PICC migration at 3% (5/164) or 0.35/1000 catheter days, and thrombosis at 2.4% (4/164) or 0.28/1000 catheter days. The median time to complication was 41 days. Those with complications were more likely to have a gastro-intestinal or an ovarian cancer diagnosis, and less likely to have colorectal cancer. These findings provide support for the safe and effective use of polyurethane (Arrow(TM)) PICCs for venous access within the adult oncology context. Furthermore, it suggests that cost effective nurse-led (Arrow(TM)) PICC insertions can contribute to a low complication rate.  
  Call Number NRSNZNO @ research @ Serial 1222  
Permanent link to this record
 

 
Author Börner, Heidi.E url  openurl
  Title Evaluating safe patient handling systems: Is there a better way? Type (up)
  Year 2008 Publication Abbreviated Journal ResearchArchive@Victoria  
  Volume Issue Pages  
  Keywords Patient safety; Evaluation research; Occupational health and safety  
  Abstract This observational study analyses the responses of 38 nurses from two similar units that use different patient handling systems to test the reliability and validity of the Safe Patient Handling Survey (TM) SPH Survey(TM), a perception survey and improvement tool for employees and employers. Currently there is a lack of tools for evaluating patient handling systems. The survey contains 55 questions divided into 6 clusters, staff and patient injury and violence questions, and picture questions depicting unsafe techniques. The data were analysed to see how the SPH Survey(TM) scores correlate with incidents, and its ability to detect differences between the two units. The results of the Pearson and Cronbach(TM) alpha tests show strong reliability, validity and consistency of the SPH Survey(TM). ANOVA comparison of means and Spearman(TM) rho tests shows that higher (better) scores on the SPH Survey(TM) clusters correlate with lower numbers of patient injuries, lower reports of verbal and physical violence episodes, and lower staff injuries. Differences were detected between the units with Unit 2 scoring higher than Unit 1 in all SPH Survey(TM) clusters and scoring lower in staff and patient injuries and violence incidents. Although the analysis was limited by the small sample size, the study has created a sound basis for further investigation. The SPH Survey(TM) is shown to be an easy way to reliably evaluate patient handling systems and workplace culture, target improvement initiatives, and continually monitor the level of patient handling risk in the workplace. Low-risk patient handling gives health care providers the means to focus on delivering high quality patient care, without endangering their own health and well-being.  
  Call Number NRSNZNO @ research @ Serial 1224  
Permanent link to this record
Select All    Deselect All
 |   | 